Reznor model UBX gas-fired unit heaters are great for space heating applications.
These units are power vented to eliminate heat losses up the flue pipe. UDX and UBX models are available in 14 sizes ranging from 30,000 to 400,000 BTUH gas input and are approved for installation in the United States and Canada by ETL. UBX unit heaters feature a two-tone black and white powder-coated, scratch-resistant paint scheme. Each unit has clean rounded corners and edges with no visible screws or fasteners. Each size cabinet is easily suspended from 4 suspension points. The low voltage terminal strip on the outside of the cabinet makes connecting control wiring easy with no panels to remove. The addition of a terminal to the strip, along with the new design of the circuit board, allows for fan-only operation (without adding relays).
Reznor Model UBX Features and Benefits:
Certified for commercial/industrial heating application
45-75 °F Rise range - Sizes 30-350
50-80 °F Rise range - Size 400
Integrated circuit board with 7 segment display
External status indicating LED
Hinged Door with ¼ turn latch
Improved cabinet design with removeable front face and two tone white and black powder paint.
Patented single burner combustion system including a onepiece burner assembly
115V, 1 phase, 60 Hz Supply voltage
115 Volt open drip proof blower motor with internal overload protection - Sizes 30-125
115 Volt open drip proof blower motor with internal overloads and definite purpose motor contactor - Sizes 150-400
Direct drive blower with multispeed taps - Sizes 30-125
Adjustable belt drive blower - Sizes 150-400
Transformer for 24-volt controls
Integrated circuit board with diagnostic indicator lights
Multi-try direct spark ignition with timed lockout
Blower relay (included on the circuit board)
Single-stage natural gas valve (field adjustable for operation to 9,000 ft. elevation)*
Vibration/noise isolated fan and venter motors ~ designed for low noise operation
4-pt Suspension ~ standard on all sizes
External terminal strip for 24-volt wiring
External gas pipe connection
Reznor Model UBX Optional Features:
Single-stage propane gas valve (field adjustable for operation to 9,000 ft.)*
Two-stage gas valve (sizes 60-400)
409 or 316 stainless steel heat exchangers
Totally enclosed blower motor (sizes 30-400)
Vent cap
Thermostat
Intergrated 30 ° & 60 ° downturn nozzles
Integrated vertical louvers.
Gas conversion kits (natural and propane)
Primary/secondary controls for zoning up to six units
Duct Flange
Polytube adapters
Hanger kits for 1" pipe
Stepdown transformer (for 208/115, 230/115 or 460/115 supply voltage)
Manual shutoff valves
Note:For installations where dirt, dust, and other airborne contamination is presenet in the indoor envirmonet, it is recommended to use seperated combustion units (Model UBZ). These models use air from outside the space for combustion. This will help reduce the build up of contaminates on the burner which would affect the combustion process. Refer to the installation manuals for recommended frequency of maintenace and cleaning.
Hydrobuilder made good on the screwup of sending a wrong part. Refunded and then I received 2 of the power adapters. I had reordered as soon as I realized tge problem with the first order. Thank you Hydrobuilders! Ill be a repeat customer!!