AXEON Water Technologies Product Documents
Axeon R1 Series Specsheet Axeon System Warranty Information The Importance of Water AnalysisAXEON R1–Series Reverse Osmosis Systems are designed for overall superior performance, high recovery rates, minimal energy consumption and offer great savings with low maintenance and low operation costs.
R1–Series Reverse Osmosis Systems feature a new, innovative design. These systems feature only the highest quality components, including a programmable computer controller with many builtin standard features, a stainless steel booster pump for high performance and corrosion resistance, ultra housings for enhanced performance and durability.
R1–Series Reverse Osmosis Systems have been engineered for capacities ranging from 1,800-21,600 gallons per day
BENEFITS
- Fully Equipped and Customizable
- Skid Mounted
- Decreased Size of Dimensional Footprint from Standard Reverse Osmosis Systems
- Components Easily Accessible
- Pre-Plumbed, Wired and Assembled
- Individually Tested and Preserved
- Low Operation and Maintenance Costs
- Easy Maintenance and Servicing
- 20% Less Energy Use than Standard Reverse Osmosis Systems
- 1-Year Limited Warranty
FEATURES
- S–150 Computer Controller
- LCD Backlit Display
- Pre-Treatment Lockout
- Tank Level Input
- Low Pressure Monitoring and Alarm
- Hour Meter
- TDS Monitoring
- Feed Flush
- AXEON Permeate and Concentrate Flow Meters
- AXEON Concentrate Recycle Flow Meter
- AXEON Pre-Filter 0-100 psi Panel Mounted Glycerin Filled Gauges
- AXEON Pump Discharge and Concentrate 0-300 psi Panel Mounted Glycerin Filled Gauges
- AXEON 5-Micron Sediment Pre-Filter
- AXEON HF5 – Series Ultra Low Energy Membrane Elements
- AXEON FRP– Series Membrane Housings (300 psi)
- AXEON by Pentair® 20" Big Grey Cartridge Housings
- Goulds Multi-Stage Stainless Steel Booster Pump
- ASCO Composite Feed Solenoid Valve
- Feed Low Pressure Switch
- White Powder Coated Aluminum Frame
- Dual Chemical Pump Outlets
A Closer Look At The R1 Series

- 1.) Filter In - Measures feed pressure which needs a minimum > 45 psi. Lower pressure can create low pressure faults.
- 2.) Differential pressure is measured based on the Filter In and Filter Out and if it exceeds
- 3.) Filter Out - Pressure must be above > 40 psi. Low pressure switch will shut off unit when it goes below < 15 psi.
- 4.) Pump Pressure - Displays pressure after the RO Pump and before
- 5.) If differential pressure on these two gauges shows above 15 psi per each membrane housing (ex. 3 membranes in series would add up to 45+ psi) then membrane likely is fouled. Clean or replace membranes.
- 6.) Concentrate Pressure - Displays pressure after the last membrane.
- 7.) S150 Controller - Monitors functions from TDS, temperature, rejection (with dual TDS Option) RO pump, pressures and solenoid valve. Voltage standard is 220 1 pH and optional 3 pH, voltage 380, 460, 575 VAC. This controller is UL/CL certified
- 8.) Permeate - Shows the amount of water being produced in GPM (Gallons Per Minute), also known as Product Water.
- 9.) Concentrate/Concentrate Valve - Measures flows of waste water using an integrated needle valve to adjust pressure and flows
- 10.) Concentrate Recycle/Concentrate Recycle Valve - Measures flows of recycled water from the waste water side for higher recover using an integrated needle valve to adjust flows. This is used in conjunction with concentrate water.
- 11.) Solenoid Valve - The ASCO brand solenoid is a composite valve that lets water in or stops based on RO demand. The size is 1" FNPT (female pipe thread). ALWAYS have the same size or larger pipe.
- 12.) Sediment Filter - This uses a 4.5" x 20" filter that traps particulates as low as 5 microns using a 5 mic filter


- 13.) RO Pump - This produces the required pressure for the RO system. The R1 has two sizes: 1.5 hp for the R1–1140 to R1– 4140 and 3 hp for the R1–5140 to R1–12140.
- 14.) Injection Port - This is for the injector used in a chemical injection system. This injects a chemical to help prevent fouling of the membrane. S200 is the chemical used to sequester hardness so it won't plug the membranes. Up to 300 GPG.
- 15.) Pump Throttle Valve -This controls the flow and pressure from the pump. NEVER fully close this or damage will occur from heat and dead heading.
- 16.) Fiberglass Pressure Valve - Stores membranes (HF5– 4040) that produce clean water.
- 16.) Injection Power - Power source only for the chemical injection pump. It is not to be used for anything else or overloading can occur.
SPECIFICATIONS
R1-2140 | R1-4140 | R1-8140 | ||
---|---|---|---|---|
Design | ||||
Configuration | Single Span | |||
Feedwater TDS max (ppm)a | 2,000 | |||
Standard Recovery % | 29 | 63 | 63 | |
Rejection and Flow Rates | ||||
Permeate Flow Rate (GPM) | 3,600 | 7,200 | 14,400 | |
Permeate Flow (GPD) | 2.5 | 5 | 37.85 | |
Minimum Concentrate Flow (GPM) | 3 | 3 | 6 | |
Concentrate Recycle Flow Rate (GPM) | Up to 5 | |||
Connections | ||||
Feed Connection (in) | 1 FNPT | |||
Permeate Connection (in) | 3/4 FNPT | 1 FNPT | 1 FNPT | |
Concentrate Connection (in) | 3/4 FNPT | 1 FNPT | 1 FNPT | |
Membranes | ||||
Membranes Per Vessel | 1 | |||
Membrane Quantity | 2 | 4 | 8 | |
Membrane Size | 4040 | |||
Nominal TDS Rejection % | 98.5 | |||
Membrane Quantity | 2 | 4 | 8 | |
Vessels | ||||
Vessel Array | 1:1 | 1:1:1:1 | 2:2:2:2 | |
Vessel Quantity | 2 | 4 | 8 | |
Pumps | ||||
Pump Type | Multi-Stage | |||
Motor HP | 1.5 | 1.5 | 3 | |
RPM @ 60Hz | 3450 | |||
System Electrical | ||||
Standard Voltage + Amp Draw | 220V, 60Hz, 1PH, 8.8AC | 220V, 60Hz, 1PH, 8.8AC | 220V, 60Hz, 1PH, 16AC | |
System Dimensions | ||||
Approximate Dimensions LxWxH (in) | 26 x 26 x 60 | 32 x 26 x 60 | 32 x 50 x 60 | |
Approximate Weight (lbs) | 290 | 370 | 510 |
OPERATING LIMITS
Maximum Feed Temperature (°F/°C) | 85/29 |
---|---|
Minimum Feed Temperature (°F/°C) | 40 / 4 |
Maximum Ambient Temperature (°F/°C) | 1200/149 |
Minimum Ambient Temperature (°F/°C) | 40/4 |
Maximum Feed Pressure (psi / bar) | 85/6 |
Minimum Feed Pressure (psi / bar) | 45/3 |
Maximum Pressure (psi / bar) | 200/14 |
Maximum Feed Silt Density Index (SDI) | <3 |
Maximum Free Chlorine (ppm) | 0 |
---|---|
Maximum TDS (ppm) | 2,000 |
Maximum Hardness (gpg) | 0 |
Maximum pH (continuous) | 11 |
Minimum pH (continuous) | 2 |
Maximum pH (cleaning 30 minutes) | 13 |
Minimum pH (cleaning 30 minutes) | 1 |
Maximum Turbidity NTU | 1 |
Brand | AXEON Water Technologies |
---|---|
SKU | AX41401 |
Weight (lb.) | 370.0000 |
Height (in.) | |
Width (in.) | |
Length (in.) | |
Lead Time | This product ships in 4-6 weeks |
Shipping Restrictions | AK, HI |
Prop 65 | false |
Gallons Per Day | 7,200 |
Inlet Tubing Size | 1" |
Product Tubing Size | 1" |
Waste Tubing Size | 1" |
Gallons Per Hour | 300 |
Min. Feed Pressure | 45 psi |
Recommended Feed Pressure | 80 psi |
Operating Temperature | 77 degrees |
Operating pH | 7 pH |
Nominal % Rejection | 98.5 |
Max TDS | 2,000 |
Max Hardness | 0 |
Amps | 8.8 Amps |
Voltage | 220 Volts |