{"product_id":"axeon-r1-5140-reverse-osmosis-system-9000-gpd-460-volt-50hz-3-phase","title":"AXEON R1-5140 Reverse Osmosis System, 9000 GPD, 460 Volt, 50HZ, 3 Phase","description":"\u003cp\u003e\n      \u003cstrong\u003eAXEON® R1–Series Reverse Osmosis Systems\u003c\/strong\u003e are designed for overall superior performance, high recovery rates, minimal energy consumption and offer great savings with low maintenance and low operation costs.\n     \u003c\/p\u003e\n     \u003cp\u003e\n      \u003cstrong\u003eR1–Series Reverse Osmosis Systems\u003c\/strong\u003e feature a new, innovative design. These systems feature only the highest quality components, including a programmable computer controller with many builtin standard features, a stainless steel booster pump for high performance and corrosion resistance, ultra low energy membranes and fiberglass membrane housings for enhanced performance and durability.\n     \u003c\/p\u003e\n     \u003cp\u003e\n      \u003cstrong\u003eR1–Series Reverse Osmosis Systems\u003c\/strong\u003e have been engineered for capacities ranging from 1,800-21,600 gallons per day.\n     \u003c\/p\u003e\n     \u003ch3\u003e\u003cstrong\u003eBenefits:\u003c\/strong\u003e\u003c\/h3\u003e\n     \u003cul style=\"list-style: disc;\"\u003e\n      \u003cli\u003eFully Equipped and Customizable\u003c\/li\u003e\n      \u003cli\u003eSkid Mounted\u003c\/li\u003e\n      \u003cli\u003eDecreased Size of Dimensional Footprint from Standard Reverse Osmosis Systems\u003c\/li\u003e\n      \u003cli\u003eComponents Easily Accessible\u003c\/li\u003e\n      \u003cli\u003ePre-Plumbed, Wired and Assembled\u003c\/li\u003e\n      \u003cli\u003eIndividually Tested and Preserved\u003c\/li\u003e\n      \u003cli\u003eLow Operation and Maintenance Costs\u003c\/li\u003e\n      \u003cli\u003eEasy Maintenance and Servicing\u003c\/li\u003e\n      \u003cli\u003e20% Less Energy Use than Standard Reverse Osmosis Systems\u003c\/li\u003e\n      \u003cli\u003e1-Year Limited Warranty\u003c\/li\u003e\n     \u003c\/ul\u003e\n\n     \u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n     \u003cul style=\"list-style: disc;\"\u003e\n      \u003cli\u003eS–150 Computer Controller\n       \u003cul class=\"mb-0\" style=\"list-style: disc;\"\u003e\n        \u003cli\u003eLCD Backlit Display\n        \u003c\/li\u003e\n\u003cli\u003ePre-Treatment Lockout\n        \u003c\/li\u003e\n\u003cli\u003eTank Level Input\n        \u003c\/li\u003e\n\u003cli\u003eLow Pressure Monitoring and Alarm\n        \u003c\/li\u003e\n\u003cli\u003eHour Meter\n        \u003c\/li\u003e\n\u003cli\u003eTDS Monitoring\n        \u003c\/li\u003e\n\u003cli\u003eFeed Flush\n       \u003c\/li\u003e\n\u003c\/ul\u003e\n      \u003c\/li\u003e\n      \u003cli\u003eAXEON Permeate and Concentrate Flow Meters\u003c\/li\u003e\n      \u003cli\u003eAXEON Concentrate Recycle Flow Meter\u003c\/li\u003e\n      \u003cli\u003eAXEON Pre-Filter 0-100 psi Panel Mounted Glycerin Filled Gauges\u003c\/li\u003e\n      \u003cli\u003eAXEON Pump Discharge and Concentrate 0-300 psi Panel Mounted Glycerin Filled Gauges\u003c\/li\u003e\n      \u003cli\u003eAXEON 5-Micron Sediment Pre-Filter\u003c\/li\u003e\n      \u003cli\u003eAXEON HF5 – Series Ultra Low Energy Membrane Elements\u003c\/li\u003e\n      \u003cli\u003eAXEON FRP– Series Membrane Housings (300 psi)\u003c\/li\u003e\n      \u003cli\u003eAXEON by Pentair® 20\" Big Grey Cartridge Housings\u003c\/li\u003e\n      \u003cli\u003eMulti-Stage Stainless Steel Booster Pump\u003c\/li\u003e\n      \u003cli\u003eComposite Feed Solenoid Valve\u003c\/li\u003e\n      \u003cli\u003eFeed Low Pressure Switch\u003c\/li\u003e\n      \u003cli\u003eWhite Powder Coated Aluminum Frame\u003c\/li\u003e\n      \u003cli\u003eDual Chemical Pump Outlets\u003c\/li\u003e\n     \u003c\/ul\u003e\u0026gt;AXEON R1–Series Reverse Osmosis Systems are designed for overall superior performance, high recovery rates, minimal energy consumption and offer great savings with low maintenance and low operation costs.\n\n    \u003cp\u003eR1–Series Reverse Osmosis Systems feature a new, innovative design. These systems feature only the highest quality components, including a programmable computer controller with many builtin standard features, a stainless steel booster pump for high performance and corrosion resistance, ultra housings for enhanced performance and durability.\u003c\/p\u003e\n\n    \u003cp\u003eR1–Series Reverse Osmosis Systems have been engineered for capacities ranging from 1,800-21,600 gallons per day\u003c\/p\u003e\n\n\u003chr\u003e\n\n    \u003cp class=\"fw-bold fs-3\"\u003eBENEFITS\u003c\/p\u003e\n    \u003cdiv class=\"row\"\u003e\n        \u003cdiv class=\"col-md-6 col-lg-6 col-xl-6\"\u003e\n\n\u003cul\u003e\n\u003cli\u003eFully Equipped and Customizable\u003c\/li\u003e\n\u003cli\u003eSkid Mounted\u003c\/li\u003e\n\u003cli\u003eDecreased Size of Dimensional Footprint from Standard Reverse Osmosis Systems\u003c\/li\u003e\n\u003cli\u003eComponents Easily Accessible\u003c\/li\u003e\n\u003cli\u003ePre-Plumbed, Wired and Assembled\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"col-md-6 col-lg-6 col-xl-6\"\u003e\n\u003cul\u003e\n\u003cli\u003eIndividually Tested and Preserved\u003c\/li\u003e\n\u003cli\u003eLow Operation and Maintenance Costs\u003c\/li\u003e\n\u003cli\u003eEasy Maintenance and Servicing\u003c\/li\u003e\n\u003cli\u003e20% Less Energy Use than Standard Reverse Osmosis Systems\u003c\/li\u003e\n\u003cli\u003e1-Year Limited Warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n    \u003chr\u003e\n        \u003cp class=\"fw-bold fs-3\"\u003eFEATURES\u003c\/p\u003e\n            \u003cdiv class=\"row\"\u003e\n                \u003cdiv class=\"col-md-4 col-lg-4 col-xl-4\"\u003e\n\n                    \u003cul\u003e\n                        \u003cli\u003eS–150 Computer Controller\n                            \u003cul class=\"mb-0\"\u003e\n                                \u003cli\u003eLCD Backlit Display\u003c\/li\u003e\n                                \u003cli\u003ePre-Treatment Lockout\u003c\/li\u003e\n                                \u003cli\u003eTank Level Input\u003c\/li\u003e\n                                \u003cli\u003eLow Pressure Monitoring and Alarm\u003c\/li\u003e\n                                \u003cli\u003eHour Meter\u003c\/li\u003e\n                                \u003cli\u003eTDS Monitoring\u003c\/li\u003e\n                                \u003cli\u003eFeed Flush\u003c\/li\u003e\n                            \u003c\/ul\u003e\n                        \u003c\/li\u003e\n                        \u003cli\u003eAXEON Permeate and Concentrate Flow Meters\u003c\/li\u003e\n                        \u003cli\u003eAXEON Concentrate Recycle Flow Meter\u003c\/li\u003e\n                    \u003c\/ul\u003e\n                \u003c\/div\u003e\n\n\n                \u003cdiv class=\"col-md-4 col-lg-4 col-xl-4\"\u003e\n                    \u003cul\u003e\n                        \n                        \u003cli\u003eAXEON Pre-Filter 0-100 psi Panel Mounted Glycerin Filled Gauges\u003c\/li\u003e\n                        \u003cli\u003eAXEON Pump Discharge and Concentrate 0-300 psi Panel Mounted Glycerin Filled Gauges\u003c\/li\u003e\n                        \u003cli\u003eAXEON 5-Micron Sediment Pre-Filter\u003c\/li\u003e\n                        \u003cli\u003eAXEON HF5 – Series Ultra Low Energy Membrane Elements\u003c\/li\u003e\n                        \u003cli\u003eAXEON FRP– Series Membrane Housings (300 psi)\u003c\/li\u003e\n                    \u003c\/ul\u003e\n                \u003c\/div\u003e\n\n                \u003cdiv class=\"col-md-4 col-lg-4 col-xl-4\"\u003e\n                    \u003cul\u003e\n                        \u003cli\u003eAXEON by Pentair® 20\" Big Grey Cartridge Housings\u003c\/li\u003e\n                        \u003cli\u003eGoulds Multi-Stage Stainless Steel Booster Pump\u003c\/li\u003e\n                        \u003cli\u003eASCO Composite Feed Solenoid Valve\u003c\/li\u003e\n                        \u003cli\u003eFeed Low Pressure Switch\u003c\/li\u003e\n                        \u003cli\u003eWhite Powder Coated Aluminum Frame\u003c\/li\u003e\n                        \u003cli\u003eDual Chemical Pump Outlets\u003c\/li\u003e\n                    \u003c\/ul\u003e\n                \u003c\/div\u003e\n            \u003c\/div\u003e\n\n\u003chr\u003e\n\u003cdiv class=\"row\"\u003e\n    \u003cp class=\"fw-bold fs-3 text-center\"\u003eA Closer Look At The R1 Series\u003c\/p\u003e\n    \u003cdiv class=\"col-md-12 col-lg-12 col-xl-6\"\u003e\n  \u003cdiv class=\"daspect\" style=\"--ratio:101.11%\"\u003e\n                    \u003cimg alt=\"Layout 1-12\" title=\"System layout 1-2\" class=\"cfresize_600\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0910\/5912\/6550\/files\/Axeon_r1_system_1_12_layout_desc_image_2023.png?v=1740548663\" width=\"100%\"\u003e\n                \u003c\/div\u003e\n    \n\n\u003cul style=\"list-style-type:none\" class=\"mb-0\"\u003e \n            \u003cli\u003e\n\u003cstrong class=\"fs-5\"\u003e1.) \u003c\/strong\u003e\u003cstrong\u003eFilter In\u003c\/strong\u003e - Measures feed pressure which needs a minimum \u0026gt; 45 psi. Lower pressure can create low pressure faults.\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong class=\"fs-5\"\u003e2.) \u003c\/strong\u003eDifferential pressure is measured based on the Filter In and Filter Out and if it exceeds\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n    \n    \u003cdiv class=\"col-md-12 col-lg-12 col-xl-6\"\u003e\n         \n\u003cul style=\"list-style-type:none\"\u003e \n\u003cli\u003e\n\u003cstrong class=\"fs-5\"\u003e3.) \u003c\/strong\u003e\u003cstrong\u003eFilter Out\u003c\/strong\u003e - Pressure must be above \u0026gt; 40 psi. Low pressure switch will shut off unit when it goes below \u0026lt; 15 psi.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong class=\"fs-5\"\u003e4.) \u003c\/strong\u003e\u003cstrong\u003ePump Pressure\u003c\/strong\u003e - Displays pressure after the RO Pump and before\u003c\/li\u003e\n\n\n\u003cli\u003e\n\u003cstrong class=\"fs-5\"\u003e5.) \u003c\/strong\u003eIf differential pressure on these two gauges shows above 15 psi per each membrane housing (ex. 3 membranes in series would add up to 45+ psi) then membrane likely is fouled. Clean or replace membranes.\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong class=\"fs-5\"\u003e6.) \u003c\/strong\u003e\u003cstrong\u003eConcentrate Pressure\u003c\/strong\u003e - Displays pressure after the last membrane.\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong class=\"fs-5\"\u003e7.) \u003c\/strong\u003e\u003cstrong\u003eS150 Controller\u003c\/strong\u003e - Monitors functions from TDS, temperature, rejection (with dual TDS Option) RO pump, pressures and solenoid valve. Voltage standard is 220 1 pH and optional 3 pH, voltage 380, 460, 575 VAC. This controller is UL\/CL certified\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong class=\"fs-5\"\u003e8.) \u003c\/strong\u003e\u003cstrong\u003ePermeate\u003c\/strong\u003e - Shows the amount of water being produced in GPM (Gallons Per Minute), also known as Product Water.\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong class=\"fs-5\"\u003e9.) \u003c\/strong\u003e\u003cstrong\u003eConcentrate\/Concentrate Valve\u003c\/strong\u003e - Measures flows of waste water using an integrated needle valve to adjust pressure and flows\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong class=\"fs-5\"\u003e10.) \u003c\/strong\u003e\u003cstrong\u003eConcentrate Recycle\/Concentrate Recycle Valve\u003c\/strong\u003e - Measures flows of recycled water from the waste water side for higher recover using an integrated needle valve to adjust flows. This is used in conjunction with concentrate water.\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong class=\"fs-5\"\u003e11.) \u003c\/strong\u003e\u003cstrong\u003eSolenoid Valve\u003c\/strong\u003e - The ASCO brand solenoid is a composite valve that lets water in or stops based on RO demand. The size is 1\" FNPT (female pipe thread). ALWAYS have the same size or larger pipe.\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong class=\"fs-5\"\u003e12.) \u003c\/strong\u003e\u003cstrong\u003eSediment Filter\u003c\/strong\u003e - This uses a 4.5\" x 20\" filter that traps particulates as low as 5 microns using a 5 mic filter\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003chr\u003e\n\n\u003cdiv class=\"row\"\u003e\n        \u003cdiv class=\"col-md-12 col-lg-6 col-xl-6\"\u003e\n  \u003cdiv class=\"daspect\" style=\"--ratio:100%\"\u003e\n                    \u003cimg alt=\"13-16 System\" title=\"System 13-16 system layout\" class=\"cfresize_600\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0910\/5912\/6550\/files\/Axeon_r1_system_13_16_layout_desc_image_2023.png?v=1740548663\" width=\"100%\"\u003e\n                \u003c\/div\u003e\n\n            \u003c\/div\u003e\n        \u003cdiv class=\"col-md-12 col-lg-6 col-xl-6\"\u003e\n                  \u003cdiv class=\"daspect\" style=\"--ratio:100%\"\u003e\n                    \u003cimg alt=\"17 layout\" title=\"17 system layout\" class=\"cfresize_600\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0910\/5912\/6550\/files\/Axeon_r1_system_17_layout_desc_image_2023.png?v=1740548663\" width=\"100%\"\u003e\n                \u003c\/div\u003e\n            \u003c\/div\u003e\n\n\n\n\n\n        \u003cdiv class=\"col-md-12 col-lg-12 col-xl-6\"\u003e\n\u003cul style=\"list-style-type:none\"\u003e \n\u003cli\u003e\n\u003cstrong class=\"fs-5\"\u003e13.) \u003c\/strong\u003e\u003cstrong\u003eRO Pump\u003c\/strong\u003e - This produces the required pressure for the\nRO system. The R1 has two sizes: 1.5 hp for the R1–1140 to R1– 4140 and 3 hp for the R1–5140 to R1–12140.\u003c\/li\u003e\n\n\n\u003cli\u003e\n\u003cstrong class=\"fs-5\"\u003e14.) \u003c\/strong\u003e\u003cstrong\u003eInjection Port\u003c\/strong\u003e - This is for the injector used in a chemical injection system. This injects a chemical to help prevent fouling of the membrane. S200 is the chemical used to sequester hardness so it won't plug the membranes. Up to 300 GPG.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\n        \u003cdiv class=\"col-md-12 col-lg-12 col-xl-6\"\u003e\n\u003cul style=\"list-style-type:none\"\u003e \n\u003cli\u003e\n\u003cstrong class=\"fs-5\"\u003e15.) \u003c\/strong\u003e\u003cstrong\u003ePump Throttle Valve\u003c\/strong\u003e -This controls the flow and pressure from the pump. NEVER fully close this or damage will occur from heat and dead heading. \u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong class=\"fs-5\"\u003e16.) \u003c\/strong\u003e\u003cstrong\u003eFiberglass Pressure Valve\u003c\/strong\u003e - Stores membranes (HF5– 4040) that produce clean water.\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong class=\"fs-5\"\u003e16.) \u003c\/strong\u003e\u003cstrong\u003eInjection Power\u003c\/strong\u003e - Power source only for the chemical injection pump. It is not to be used for anything else or overloading can occur. \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003chr\u003e\n\n\u003cp class=\"fw-bold fs-3\"\u003eSPECIFICATIONS\u003c\/p\u003e\n\n            \u003ctable class=\"custom-spec-table text-center mb-3\" width=\"100%\"\u003e\n                \u003cthead\u003e\n                    \u003ctr class=\"fw-bold\"\u003e\n                        \u003cth style=\"border-top: none; border-left: none;\"\u003e \u003c\/th\u003e                    \n                        \u003cth\u003eR1-2140\u003c\/th\u003e\n                        \u003cth\u003eR1-4140\u003c\/th\u003e\n                        \u003cth\u003eR1-8140\u003c\/th\u003e\n                    \u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n                    \u003ctr\u003e\n                        \u003ctd colspan=\"4\" class=\"fw-bold\" style=\" text-align: left; text-indent: 2%;\"\u003eDesign\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr\u003e\n                        \u003ctd\u003eConfiguration\u003c\/td\u003e\n                        \u003ctd colspan=\"4\"\u003eSingle Span\u003c\/td\u003e\n\n                    \u003c\/tr\u003e\n                    \u003ctr\u003e\n                        \u003ctd\u003eFeedwater TDS max (ppm)\u003csup\u003ea\u003c\/sup\u003e\n\u003c\/td\u003e\n                        \u003ctd colspan=\"4\"\u003e2,000\u003c\/td\u003e\n\n                    \u003c\/tr\u003e\n                    \u003ctr\u003e\n                        \u003ctd\u003eStandard Recovery %\u003c\/td\u003e\n                        \u003ctd\u003e29\u003c\/td\u003e\n                        \u003ctd\u003e63\u003c\/td\u003e\n                        \u003ctd\u003e63\u003c\/td\u003e\n\n                    \u003c\/tr\u003e\n                    \u003ctr\u003e\n                    \u003ctd colspan=\"4\" style=\" text-align: left; text-indent: 2%;\" class=\"fw-bold\"\u003eRejection and Flow Rates\u003c\/td\u003e\n                \u003c\/tr\u003e\n                    \u003ctr\u003e\n                        \u003ctd\u003ePermeate Flow Rate (GPM)\u003c\/td\u003e\n                        \u003ctd\u003e3,600\u003c\/td\u003e\n                        \u003ctd\u003e7,200\u003c\/td\u003e\n                        \u003ctd\u003e14,400\u003c\/td\u003e\n\n                    \u003c\/tr\u003e\n                    \u003ctr\u003e\n                        \u003ctd\u003ePermeate Flow (GPD)\u003c\/td\u003e\n                        \u003ctd\u003e2.5\u003c\/td\u003e\n                        \u003ctd\u003e5\u003c\/td\u003e\n                        \u003ctd\u003e37.85\u003c\/td\u003e\n\n                    \u003c\/tr\u003e\n\n                    \u003ctr\u003e\n                        \u003ctd\u003eMinimum Concentrate Flow (GPM) \u003c\/td\u003e\n                        \u003ctd\u003e3\u003c\/td\u003e\n                        \u003ctd\u003e3\u003c\/td\u003e\n                        \u003ctd\u003e6\u003c\/td\u003e\n\n                    \u003c\/tr\u003e\n                    \u003ctr\u003e\n                        \u003ctd\u003eConcentrate Recycle Flow Rate (GPM)\u003c\/td\u003e\n                        \u003ctd colspan=\"4\"\u003eUp to 5\u003c\/td\u003e\n\n                    \u003c\/tr\u003e         \n\n                                \u003ctr\u003e\n                    \u003ctd colspan=\"4\" style=\" text-align: left; text-indent: 2%;\" class=\"fw-bold\"\u003eConnections\u003c\/td\u003e\n                \u003c\/tr\u003e\n                    \u003ctr\u003e\n                        \u003ctd\u003eFeed Connection (in)\u003c\/td\u003e\n                        \u003ctd colspan=\"4\"\u003e1 FNPT\u003c\/td\u003e\n \n \n                    \u003c\/tr\u003e\n                       \u003ctr\u003e\n                        \u003ctd\u003ePermeate Connection (in)\u003c\/td\u003e\n                        \u003ctd\u003e3\/4 FNPT\u003c\/td\u003e\n                        \u003ctd\u003e1 FNPT\u003c\/td\u003e\n                        \u003ctd\u003e1 FNPT\u003c\/td\u003e\n                    \u003c\/tr\u003e\n\n                       \u003ctr\u003e\n                        \u003ctd\u003eConcentrate Connection (in)\u003c\/td\u003e\n                        \u003ctd\u003e3\/4 FNPT\u003c\/td\u003e\n                        \u003ctd\u003e1 FNPT\u003c\/td\u003e\n                        \u003ctd\u003e1 FNPT\u003c\/td\u003e\n                    \u003c\/tr\u003e\n\n\n                    \u003ctr\u003e\n                    \u003ctd colspan=\"4\" style=\" text-align: left; text-indent: 2%;\" class=\"fw-bold\"\u003eMembranes\u003c\/td\u003e\n                \u003c\/tr\u003e\n                    \u003ctr\u003e\n                        \u003ctd\u003eMembranes Per Vessel\u003c\/td\u003e\n                        \u003ctd colspan=\"4\"\u003e1\u003c\/td\u003e\n\n                    \u003c\/tr\u003e\n        \n                    \u003ctr\u003e\n                        \u003ctd\u003eMembrane Quantity\u003c\/td\u003e\n                        \u003ctd\u003e2\u003c\/td\u003e\n                        \u003ctd\u003e4\u003c\/td\u003e\n                        \u003ctd\u003e8\u003c\/td\u003e\n\n                    \u003c\/tr\u003e\n                    \u003ctr\u003e\n                        \u003ctd\u003eMembrane Size\u003c\/td\u003e\n                        \u003ctd colspan=\"4\"\u003e4040\u003c\/td\u003e\n\n                    \u003c\/tr\u003e\n\n                                        \u003ctr\u003e\n                        \u003ctd\u003eNominal TDS Rejection %\u003c\/td\u003e\n                        \u003ctd colspan=\"4\"\u003e98.5\u003c\/td\u003e\n                    \u003c\/tr\u003e\n\n\n\n\n\n\n                        \u003ctr\u003e\n                        \u003ctd\u003eMembrane Quantity\u003c\/td\u003e\n                        \u003ctd\u003e2\u003c\/td\u003e\n                        \u003ctd\u003e4\u003c\/td\u003e\n                        \u003ctd\u003e8\u003c\/td\u003e\n\n                    \u003c\/tr\u003e\n\n                \u003ctr\u003e\n                    \u003ctd colspan=\"4\" style=\" text-align: left; text-indent: 2%;\" class=\"fw-bold\"\u003eVessels\u003c\/td\u003e\n                \u003c\/tr\u003e\n\n      \u003ctr\u003e\n                        \u003ctd\u003eVessel Array\u003c\/td\u003e\n                        \u003ctd\u003e1:1\u003c\/td\u003e\n                        \u003ctd\u003e1:1:1:1\u003c\/td\u003e\n                        \u003ctd\u003e2:2:2:2\u003c\/td\u003e\n\n                    \u003c\/tr\u003e\n                          \u003ctr\u003e\n                        \u003ctd\u003eVessel Quantity\u003c\/td\u003e\n                        \u003ctd\u003e2\u003c\/td\u003e\n                        \u003ctd\u003e4\u003c\/td\u003e\n                        \u003ctd\u003e8\u003c\/td\u003e\n\n                    \u003c\/tr\u003e\n                     \u003ctr\u003e\n                    \u003ctd colspan=\"4\" style=\" text-align: left; text-indent: 2%;\" class=\"fw-bold\"\u003ePumps\u003c\/td\u003e\n                \u003c\/tr\u003e\n                      \u003ctr\u003e\n                        \u003ctd\u003ePump Type\u003c\/td\u003e\n                        \u003ctd colspan=\"4\"\u003eMulti-Stage\u003c\/td\u003e\n\n                    \u003c\/tr\u003e\n                          \u003ctr\u003e\n                        \u003ctd\u003eMotor HP\u003c\/td\u003e\n                        \u003ctd\u003e1.5\u003c\/td\u003e\n                        \u003ctd\u003e1.5\u003c\/td\u003e\n                        \u003ctd\u003e3\u003c\/td\u003e\n\n                    \u003c\/tr\u003e\n                          \u003ctr\u003e\n                        \u003ctd\u003eRPM @ 60Hz\u003c\/td\u003e\n                        \u003ctd colspan=\"4\"\u003e3450\u003c\/td\u003e\n                    \u003c\/tr\u003e\n\n                 \u003ctr\u003e\n                    \u003ctd colspan=\"4\" style=\" text-align: left; text-indent: 2%;\" class=\"fw-bold\"\u003eSystem Electrical\u003c\/td\u003e\n                \u003c\/tr\u003e\n                            \u003ctr\u003e\n                        \u003ctd\u003eStandard Voltage + Amp Draw\u003c\/td\u003e\n                        \u003ctd\u003e220V, 60Hz, 1PH, 8.8A\u003csup\u003eC\u003c\/sup\u003e\n\u003c\/td\u003e\n                        \u003ctd\u003e220V, 60Hz, 1PH, 8.8A\u003csup\u003eC\u003c\/sup\u003e\n\u003c\/td\u003e\n                        \u003ctd\u003e220V, 60Hz, 1PH, 16A\u003csup\u003eC\u003c\/sup\u003e\n\u003c\/td\u003e\n\n                    \u003c\/tr\u003e\n\n                 \u003ctr\u003e\n                    \u003ctd colspan=\"4\" style=\" text-align: left; text-indent: 2%;\" class=\"fw-bold\"\u003eSystem Dimensions\u003c\/td\u003e\n                \u003c\/tr\u003e\n                     \u003ctr\u003e\n                        \u003ctd\u003eApproximate Dimensions LxWxH (in)\u003c\/td\u003e\n                        \u003ctd\u003e26 x 26 x 60\u003c\/td\u003e\n                        \u003ctd\u003e32 x 26 x 60\u003c\/td\u003e\n                        \u003ctd\u003e32 x 50 x 60\u003c\/td\u003e\n\n                    \u003c\/tr\u003e\n                     \u003ctr\u003e\n                        \u003ctd\u003eApproximate Weight (lbs)\u003c\/td\u003e\n                        \u003ctd\u003e290\u003c\/td\u003e\n                        \u003ctd\u003e370\u003c\/td\u003e\n                        \u003ctd\u003e510\u003c\/td\u003e\n\n                    \u003c\/tr\u003e\n                \u003c\/tbody\u003e\n            \u003c\/table\u003e\n\n\u003cp class=\"fw-bold fs-3\"\u003eOPERATING LIMITS\u003c\/p\u003e\n\n    \u003cdiv class=\"row\"\u003e\n        \u003cdiv class=\"col-md-6 col-lg-6 col-xl-6\"\u003e\n            \u003ctable class=\"custom-spec-table text-center table\" width=\"100%\"\u003e\n                \u003ctbody\u003e\n                   \u003ctr class=\"text-center\"\u003e\n                        \u003cth class=\"fw-bold\"\u003eMaximum Feed Temperature (°F\/°C) \u003c\/th\u003e\n                        \u003ctd\u003e85\/29\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                     \u003ctr class=\"text-center\"\u003e\n                        \u003cth class=\"fw-bold\"\u003eMinimum Feed Temperature (°F\/°C)\u003c\/th\u003e\n                        \u003ctd\u003e40 \/ 4\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \n                     \u003ctr class=\"text-center\"\u003e\n                        \u003cth class=\"fw-bold\"\u003eMaximum Ambient Temperature (°F\/°C)\u003c\/th\u003e\n                        \u003ctd\u003e1200\/149\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \n                     \u003ctr class=\"text-center\"\u003e\n                        \u003cth class=\"fw-bold\"\u003eMinimum Ambient Temperature (°F\/°C)\u003c\/th\u003e\n                        \u003ctd\u003e40\/4\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \n                     \u003ctr class=\"text-center\"\u003e\n                        \u003cth class=\"fw-bold\"\u003eMaximum Feed Pressure (psi \/ bar)\u003c\/th\u003e\n                        \u003ctd\u003e85\/6\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \n                     \u003ctr class=\"text-center\"\u003e\n                        \u003cth class=\"fw-bold\"\u003eMinimum Feed Pressure (psi \/ bar)\u003c\/th\u003e\n                        \u003ctd\u003e45\/3\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                          \u003ctr class=\"text-center\"\u003e\n                        \u003cth class=\"fw-bold\"\u003eMaximum Pressure (psi \/ bar)\u003c\/th\u003e\n                        \u003ctd\u003e200\/14\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \n                     \u003ctr class=\"text-center\"\u003e\n                        \u003cth class=\"fw-bold\"\u003eMaximum Feed Silt Density Index (SDI)\u003c\/th\u003e\n                        \u003ctd\u003e\u0026lt;3\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \n                    \n                \u003c\/tbody\u003e\n            \u003c\/table\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"col-md-6 col-lg-6 col-xl-6\"\u003e\n            \u003ctable class=\"custom-spec-table text-center table\" width=\"100%\"\u003e\n                \u003ctbody\u003e\n                   \u003ctr class=\"text-center\"\u003e\n                        \u003cth colspan=\"1\" class=\"fw-bold\"\u003eMaximum Free Chlorine (ppm) \u003c\/th\u003e\n                        \u003ctd\u003e0\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                     \u003ctr class=\"text-center\"\u003e\n                        \u003cth colspan=\"1\" class=\"fw-bold\"\u003eMaximum TDS (ppm)\u003c\/th\u003e\n                        \u003ctd\u003e2,000\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \n                     \u003ctr class=\"text-center\"\u003e\n                        \u003cth colspan=\"1\" class=\"fw-bold\"\u003eMaximum Hardness (gpg)\u003c\/th\u003e\n                        \u003ctd\u003e0\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \n                     \u003ctr class=\"text-center\"\u003e\n                        \u003cth colspan=\"1\" class=\"fw-bold\"\u003eMaximum pH (continuous)\u003c\/th\u003e\n                        \u003ctd\u003e11\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \n                     \u003ctr class=\"text-center\"\u003e\n                        \u003cth colspan=\"1\" class=\"fw-bold\"\u003eMinimum pH (continuous)\u003c\/th\u003e\n                        \u003ctd\u003e2\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \n                     \u003ctr class=\"text-center\"\u003e\n                        \u003cth colspan=\"1\" class=\"fw-bold\"\u003eMaximum pH (cleaning 30 minutes)\u003c\/th\u003e\n                        \u003ctd\u003e13\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                          \u003ctr class=\"text-center\"\u003e\n                        \u003cth colspan=\"1\" class=\"fw-bold\"\u003eMinimum pH (cleaning 30 minutes)\u003c\/th\u003e\n                        \u003ctd\u003e1\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \n                     \u003ctr class=\"text-center\"\u003e\n                        \u003cth colspan=\"1\" class=\"fw-bold\"\u003eMaximum Turbidity NTU\u003c\/th\u003e\n                        \u003ctd\u003e1\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \n                \u003c\/tbody\u003e\n            \u003c\/table\u003e\n\n    \u003c\/div\u003e\n\u003c\/div\u003e","brand":"AXEON Water Technologies","offers":[{"title":"9,000 GPD \/ 460 Volt, 50HZ, 3 Phase","offer_id":51877844484374,"sku":"205407","price":14748.47,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0910\/5912\/6550\/files\/204716gp-upscaled.webp?v=1789572686","url":"https:\/\/hydrobuilder.com\/products\/axeon-r1-5140-reverse-osmosis-system-9000-gpd-460-volt-50hz-3-phase","provider":"Hydrobuilder","version":"1.0","type":"link"}