Wifi connected Environmental sensor connects directly to the Iluminar HASH Lighting Controller to deliver real-time data logging directly to a smartphone or device, no PC is required. Control and view various points of data from an unlimited number of devices with additional Relay Power Cords. Expand to multiple facilities, rooms, and zones with additional environmental sensors. Connect the Iluminar Hash Lighting Controller for high accuracy monitoring and full control of connected devices.
Monitor temperature, humidity, pressure/altitude, CO2, Vapor Pressure Deficit (VPD), and light levels.
The HASH Environmental Sensor, paired with the HASH Controller delivers real-time data logging of your grow space to you on your smartphone or device. Control and view various points of data from an unlimited number of devices with additional Power Links. Expand to multiple facilities, rooms, and zones with additional Environmental Sensors.
Like all modules, environmental sensors can be customized with name changes, and should more than one sensor be present on a Hash Lighting Controller you can average the reading across them.
Features of the HASH Environment Sensor
Connect to ILUMINAR HASH Controller for high accuracy monitoring and full control of connected devices.
Tech Specs
Hardware
Metal structures block wireless RF communication signals. If mounting the sensor inside a metal structure, make sure the HASH Controller is inside the same metal structure. The RF range can reach up to 1100 meters if there is a direct line of sight between the Environmental Sensor and the HASH Controller. In a dense industrial/greenhouse environment full of equipment & shelving, with no line of sight, the RF range is closer to 50-100 meters
Do not expose Environmental Sensor to excessively humid environments where water droplets are condensing on surfaces. This can cause both the humidity sensor and the CO2 sensor to report higher than normal readings
Cover the Environmental Sensor with a bag prior to spraying or fogging the room. It can take up to 90 seconds for the CO2 sensor to warm up (from plugging it in) for it to begin to report accurate CO2 readings. Sensor readings are most accurate between 0 and 65 °C (32 and 149 °F).
When cleaning the grow room or environment, please remove (or bag) the HASH Environmental Sensor. Neem oil or sulfur can damage the sensors
Brand | Iluminar |
---|---|
SKU | IL-HASH-ENV |
Weight (lb.) | 10 |
Lead Time | This product ships in 1-2 Business Days |
Length (in.) | 7.2 |
Width (in.) | 3.5 |
Height (in.) | 7.2 |
Warranty | 1 Year |
Prop 65 | No |
Controller Functions | Multi-Function Control |
CO2 Sensor Type | Integrated CO2 Sensor |
CO2 Function | 0 - 5000 PPM |
Remote Sensor | Yes |
Humidity Setting Range | 0 - 99.5% |
Temp Setting Range | -40 - 185 F |
Amps | 0.5 Amps |
Voltage | 25 Volts |
ETL Listed | No |
UL Listed | No |
Be the first to review this product
© 2011-2023 Hydrobuilder.com - 500 Orient Street Suite 150, Chico, CA 95928 USA
All trademarks and trade names are the property of their respective trademark holders.
20.18.4