Designed for Exceptional Performance
The new LS25 Separated Combustion Unit Heaters utilize high-temperature silicone gaskets to provide a superior seal and leakage rates that are up to 57% lower* than those allowed under ANSI Z83.8. Lennox goes above and beyond to deliver a tight, durable seal because that is the key to unmatched durability and efficiency over the life of a separated combustion product in harsh environments.
Features & Benefits
More Flexibility Keeps Everyone Comfortable.
Efficient By Design
Lennox unit heaters are designed for superior reliability and long-lasting peak performance thanks to advanced engineering and high-quality components.
Ultimate Sound Quality
The 25 series unit heaters were engineered to provide a warm and peaceful environment.
Simplified Installation & Service
Easily install and service Lennox unit heaters.
*Lennox unit heaters are the most efficient unit heaters in the 80% thermal efficiency class for models that are dual qualified for commercial and residential application, LF25-030 thru LF25-0105
** Lennox tests their products for sound and vibration in a reverberation room which is designed to measure pressure and sound levels during steady state to the standard Section 4.4.4 AHRI 260-2012. The Lennox LF25-200 and Modine 200K BTUH model were compared in May 2019.
***LF25-030 thru LF25-105
Applications and Benefits of Separated Combustion
Separated combustion LS25 models use outside air for combustion and are designed for use in applications where the indoor environment may contain airborne contaminants, VOC’s and/or dust that would normally be harmful to the combustion process and components.
Increased Application Flexibility
Lower Operating Costs
Specifications for the LS25 Heaters
Gas Heating Performance | |||
---|---|---|---|
Input Heating Capacity BTU/Hr[KW] | Output Heating Capacity BTU/Hr[KW] | Efficiency | Temp Rise °F[°C] |
125,000 [36.6] | 102,000 [29.9] | 82% | 50 [10] |
150,000 [44.0] | 123,000 [36.0] | 82% | 62 [16.7] |
175,000 [51.3] | 143,500 [42.1] | 82% | 58 [14.4] |
200,000 [58.6] | 164,000 [48.1] | 82% | 59 [15.0] |
250,000 [73.3] | 205,000 [60.1] | 82% | 51 [10.6] |
300,000 [87.9] | 246,000 [72.1] | 82% | 57 [13.9] |
400,000 [117.2] | 328,000 [96.1] | 82% | 65 [18.3] |
Connections | |||
---|---|---|---|
Gas Piping Inches | Flue Size In[MM] | Combustion Air Size In[MM] | |
1/2 | 4 [102] | 4 [102] | |
1/2 | 4 [102] | 4 [102] | |
1/2 | 5 [127] | 5 [127] | |
1/2 | 5 [127] | 5 [127] | |
3/4 | 5 [127] | 5 [127] | |
3/4 | 5 [127] | 5 [127] | |
3/4 | 6 [152] | 6 [152] |
Fan Data | |||
---|---|---|---|
Number of Fans | Air Colume CFM[M3/Min] | Amps @ 115V | Max overcurrent protection |
1 | 1950 [55.2] | 5 | 15 |
1 | 1950 [55.2] | 5 | 15 |
1 | 2350 [66.5] | 7 | 15 |
1 | 2350 [66.5] | 7 | 15 |
2 | 4000 [113.3] | 8 | 15 |
2 | 5500 [155.7] | 8 | 15 |
2 | 5500 [155.7] | 11 | 15 |
Be the first to review this product