Can Fan S-Series Inline Fans

Can Fan S-Series Inline Fans

SKU #: CAN-S-FAN

Be the first to review this product

Can Fan Brand Product
$62.24 - $74.24

Lead time: Please select an option below


Overview

The Original Can-Fan S-Series are centrifugal fans utilizing our proven German design, Swiss components and precision manufacturing.

They have carried AMCA certified numbers longer than most other fans have been around and you can be sure you’re getting every CFM we claim to deliver. The Can-Fan can be easily installed in minutes using the included mounting bracket. They have a powder-coat finish. These fans are designed for demanding continuous operation with carbon air filters and long duct runs. 100% speed controllable

Details

  • AMCA Certified performance
  • Proven Centrifugal Design
  • Power Cord Attached
  • German Engineered
  • Reliable Swiss Motor
  • Powder Coat Finish
  • Easy installtion
  • 5-year warranty
  • Available in 4", 6", 8"

Centrifugal Fans

The pressure of an incoming airstream is increased by a fan wheel, a series of blades mounted on a circular hub. Centrifugal fans move air radially — the direction of the outward flowing air is changed, usually by 90°, from the direction of the incoming air. The airflow created by centrifugal fans is directed through a system of ducts or tubes. This helps create a higher pressure airflow than axial fans. Despite a lower flow rate, centrifugal fans create a steadier flow of air than axial fans. Centrifugal fans also require a higher power input.


Model Specifications

Can-Fan S 400 120 CFM

CFM:145 at 0wg
RPM:2704
Max Watts:75
Amps:0.65 @ 120v AC 60 Hz
Diameter11.26"
Length:8.19"
Max. Height:12.75″
Blade Design:Centrifugal
Weight:7 lbs.
Inlet/Outlet4″

Recommended Filters:

Exhaust

  • Can-Lite 2600
  • Can-Lite 9000
  • Can-Lite 4×15
  • Can 33

Recirculate

  • Can-Lite 1500

Can-Fan S 600 269 CFM

CFM:270 at 0wg
RPM:2658
Max Watts:79
Amps:0.69 @ 120v AC 60 Hz
Diameter12.3″
Length:10.74″
Blade Design:Centrifugal
Weight:11 lbs.
Inlet/Outlet6″

Recommended Filters:

Exhaust

  • Can-Lite 6x16
  • Can-Lite 6x24
  • Can 33

Can-Fan S 800 483 CFM

CFM:520 at 0wg
RPM:2937
Max Watts:141
Amps:1.41@ 120v AC 60 Hz
Diameter15.2″
Length:9.4″
Blade Design:Centrifugal
Weight:12.4 lbs.
Inlet/Outlet8″

Recommended Filters:

Exhaust

  • Can-Lite 8x25
  • Can-Lite 8x40
  • Can 50
  • Can 66
  • Can 75

Recirculating

  • Can 33

Determining your requirement - Exhaust vs Recirculating (Scrubbing)

You will need to determine whether or not you are exhausting (going from a contaminated environment to a sterile environment in only a single pass through the filter) or recirculating, aka “scrubbing” (exhausting the system back into the contaminated space).

Exhaust

In an exhaust setting the air only passes through the filter one time so it is imperative that we remove as close to 100% of the contaminate as possible with that one chance. This requires that the contaminant have a certain time in contact with the carbon in order to be fully adsorbed. Our filters are marked with both exhaust and recirculating ratings for just this reason. If you are using this system to exhaust, DO NOT exceed the exhaust rating for the filter, the more this rating is exceeded the less contaminant will be adsorbed because the two will not have enough contact timefor adsorption to fully take place.

Exhaust Diagram

Recirculating

In a recirculating system, the contact time is not such a crucial number as we are taking contaminated air, filtering it, and releasing it back into what is typically and constantly decontaminated environment. It is for this reason that it is not necessary to remove 100% of the contaminant in a single pass. Instead we double the exhaust rating which will reduce the contact time, the goal here is to still remove a large portion of the contaminant but to get raise the cycle rate of air through the filter above the rate of emission from the source. Now, instead of removing 99.9% of the contaminant in a single pass we are getting closer to 60% but we are getting twice as many cycles through the filter in the same amount of time and over time, reducing the overall build-up of contaminant in the environment.

Recirculating diagram

Sizing Your Space

Once you’ve determined the type of system you need, it’s time to size your space.

Typically for exhaust we recommend a simple length x width x height /3 calculation. This will give you the amount of air (cubic feet per minute, CFM) that you will need to move to properly ventilate your space allowing for a three-minute air exchange (all the air in the space is exchanged for fresh air every three minutes). This is the number you will match your filter to.

Example:
Room size: 10’x12’x8’ (960 cubic feet)
960 cubic feet / 3 minutes = 320CFM (Minimum recommended CFM to exchange the air every 3 minutes)

For recirculating systems, you can use the same length x width x height but divide by 1.5. This will give you a high cycle rate while still ensuring the removal of a majority of contaminant with each pass through the filter.

Product Q&A

Can Fan S-Series Inline Fans Questions & Answers

Q: Is my fan Speed Controllable?
A: Yes, all of our fans are speed controllable. Note: Fans running too slowly may overheat, causing the fan to turn off. The 12″ Max-Fan™ requires the use of our variable transformer control. Only use a speed or motor control of the proper amperage to adjust the speed of the fans. Never use a light dimmer.

Reviews
Tech Specs